Credit, Dedication, Pragmatism, Excellence
Number of views:
1000

Single well oil storage tank heating

Retail price
0.0
Market price
0.0
Number of views:
1000
Product serial number
Quantity
-
+
Stock:
0
1
Product description
Parameters

1. Air source high temperature heat pump single well oil storage tank heating

Working principle:  It is mainly composed of ultra-low temperature air source high temperature heat pump, flow meter, buffer tank, circulating pump, filter and valve instrument. The process is as follows:

1, the circulating medium is pumped into the high temperature heat pump under the action of the stainless steel pipe centrifugal pump to heat up;

2, the circulating medium after heating up releases heat to the crude oil through the heat exchange coil in the tank;

3. After condensing, the circulating medium returns to the buffer tank, and is sucked by the circulating pump through the filter to circulate the initial process.

Applications:

chuangjiachuangjia

2. Circulating heating device single-well oil storage tank heating

Working principle: A circulating heating device is used to replace the gas dual-purpose furnace, a circulating pump is used for forced circulation, and an antifreeze heat transfer medium is used for heat exchange. The process plan mainly consists of heating devices, circulating pumps, liquid storage tanks, level gauges, skids, pipelines and pipe fittings, flanges, gaskets and bolts and nuts, valves and meters, operating platforms and ladders, concrete foundations, and electrical control cabinets It is composed of connecting cables and power boxes.

Flow Description:

a) The low-pressure circulating pump pumps the low-temperature return water into the heating device for heating to obtain high-temperature hot water; under the action of the pump pressure, the high-temperature hot water is pumped into the heat exchanger of the oil storage tank for heat exchange; The temperature of the water decreases, turning into low-temperature hot water and returning to the liquid storage tank, where it circulates again.

B) A flow meter is installed at the outlet of the heating device, which can analyze energy efficiency and heat exchange pipeline status through flow measurement.

C) At the junction of the heating device's water outlet and backwater outlet and the oil storage tank, a flange connection type gate valve is installed, which is convenient for operation and maintenance.

D) A basket filter is installed on the inlet side of the circulating pump to filter and protect the circulating pump.

E) Temperature, pressure display and metering devices are installed in the circulation system.

Applications: